Mastectomy and Immediate Breast Reconstruction with Pre-Pectoral or Sub- Pectoral Implant: Assessing Clinical Practice, Post-Surgical Outcomes, Patient’s Satisfaction and Cost

Author(s): Gilles Houvenaeghel, Monique Cohen, Laura Sabiani, Aurore Van Troy, Olivia Quilichini, Axelle Charavil, Max Buttarelli, Sandrine Rua, Agnès Tallet, Alexandre de Nonneville, Marie Bannier.

Immediate breast reconstruction (IBR) rates increase during last years and implant-based reconstruction was the most commonly performed procedure. We examined data collected over 25 months to assess complication rate, duration of surgery, patient’s satisfaction and cost, according to pre-pectoral or sub-pectoral implant-IBR.

All patients who received an implant-IBR, from January 2020 to January 2022, were included. Results were compared between pre-pectoral and sub-pectoral implant-IBR in univariate and multivariate analysis. We performed 316 implant-IBR, 218 sub-pectoral and 98 (31%) prepectoral. Pre-pectoral implant-IBR was significantly associated with the year (2021: OR=12.08 and 2022: OR=76.6), the surgeons and type of mastectomy (SSM vs NSM: OR=0.377).

Complications and complications Grade 2-3 rates were 12.9% and 10.1% for sub-pectoral implant-IBR respectively, without significant difference with pre-pectoral implant-IBR: 17.3% and 13.2%. Complications Grade 2-3 were significantly associated with age <50-years (OR=2.27), ASA-2 status (OR=3.63) and cup-size >C (OR=3.08), without difference between pre and sub-pectoral implant-IBR. Durations of surgery were significantly associated with cup-size C and >C (OR=1.72 and 2.80), with sentinel lymph-node biopsy and axillary dissection (OR=3.66 and 9.59) and with sub-pectoral implant-IBR (OR=2.088). Median hospitalization stay was 1 day, without difference between pre and sub-pectoral implant-IBR. Cost of surgery was significantly associated with cup-size > C (OR=2.216) and pre-pectoral implant-IBR (OR=8.02). Bad-medium satisfaction and IBRfailure were significantly associated with local recurrence (OR=8.820), post-mastectomy radiotherapy (OR=1.904) and sub-pectoral implant-IBR (OR=2.098).

Conclusion: Complications were not different between pre

© 2016-2024, Copyrights Fortune Journals. All Rights Reserved